Codesys Control

Codesys Control provides a real-time environment to run PLC programs for machine control.

To establish a connection from the NOA Bus to a Codesys Control follow this checklist.


➡ For details see Set up C6C3 for Control


Check ...

  • Codesys Gateway which is connected to the target device
    • May be any Codesys Gateway on the network
    • Install Codesys Gateway as NOA App if there is no other gateway available
  • Codesys Control as NOA App
  • Deploy a working PLC program to the target device in Codesys Control (use COMBIVIS Studio 6 for this)
  • Provide a proper Symbol Configuration i.e. with some data exported (r/o or r/w), make sure at least one variable has at least read access
  • Run it on the device (check for a green "RUN" indicator in COMBIVIS Studio 6)
    • Install is as a boot-up program (menu "Online") if appropriate
  • Set user name and password for "Secure Connection" in Codesys Communication app
    • The C6 Compact 3 requires an authorized connection to the Codesys Runtime
    • The username and password is set up in COMBIVIS Studio 6 upon first connection to the target device